    摘要:

    目的 针对桡骨远端骨折外固定支具缺乏腕关节阶段性功能锻炼的问题,提出一种基于瞬态分析的外固定支具结构优化设计方法,为外固定支具结构设计提供理论参考依据。方法 确定外固定支具固定、牵伸、活动3种工作模式,围绕牵伸、活动模式进行瞬态动力学分析,以判断其在牵伸、活动载荷作用下应力、变形等变化。对外固定支具的重要尺寸进行灵敏度分析,筛选出关键尺寸,以此为设计变量,以质量、最大变形量为目标变量。采用正交试验法、模糊优化方法建立数学模型,使多目标问题变为单目标问题,进而通过遗传算法优化求解。结果 所设计的外固定支具在牵伸、活动模式下均满足设计需求,且具有较强的刚性。经尺寸优化求解,优化后模型与原模型相比质量下降5%,最大变形减少8%。结论 研究结果达到轻量化的目的,为桡骨远端骨折外固定支具改进设计和研究奠定基础。

    Abstract:

    Objective In term of the issue that external fixator for distal radius fractures was lack of phased functional exercise of the wrist, a method for optimizing the design of external fixator structures based on transient analysis was proposed, so as to provide theoretical references for the design of external fixator structure. Methods Three working modes, namely, fixation, traction and flexibility were determined. Transient dynamic analysis was carried out targeting at the traction and flexibility mode of external fixator, so as to judge its stress and displacement changes under traction and flexibility loads. The key dimensions of external fixator were selected by sensitivity analysis, so as to screen out the important dimensions, and mass and maximum displacement were selected as target variables. Orthogonal test method and fuzzy optimization method were used to establish the mathematical model to change the multi-objective problem into a single objective problem, and then genetic algorithm was used to optimize the solution. Results The design of external fixator met design requirements in both traction and flexibility modes, with a stronger rigidity. The dimensional optimization has result ed in a 5% reduction in mass and an 8% reduction in maximum deformation compared to the original model. Conclusions This study achieves the goal of lightweight design and lays the foundation for improved design and research of external fixator for distal radius fractures.

    参考文献
    相似文献
    引证文献
引用本文

张 静,萨日娜,嘎拉台.基于瞬态分析的桡骨远端骨折外固定支具结构优化设计[J].医用生物力学,2022,37(5):952-959

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2021-12-20
  • 最后修改日期:2022-01-24
  • 录用日期:
  • 在线发布日期: 2022-10-25
  • 出版日期:
关闭