    摘要:

    目的探讨股骨颈骨折术后植入空心钉及钢板后,髋关节固有和约束模态对内固定的影响。方法 对1名股骨颈骨折患者CT图像数据进行分析,提取髋关节边界生成髋关节三维模型,并建立常用内固定模型与髋关节模型装配,进行有限元仿真,重点分析振动特性。结果 振动对空心钉、钢板的内固定稳定性有一定影响,扭转的发生将破坏空心钉、钢板的固定环境,在骨折断端产生微小位移;在约束状态下,模态频率范围较低,振型的变形多发生在股骨头近端处,导致内固定以及假体发生松动的现象。从振动特性角度提出一种评判内固定稳定性的方法,发现空心钉内固定的稳定性优于近端锁定钢板。结论 选用内固定时需要考虑螺钉、钢板固有频率的影响,避免与股骨的固有频率相近,导致谐振的产生。研究结果对指导内固定材料的选用和结构、排列的设计具有一定借鉴作用。

    Abstract:

    Objective To investigate the influence from natural and constrained modal of the hip joint on internal fixation after implantation of hollow screws and locking plates for treating femoral neck fractures. Methods CT image data of a patient with femoral neck fracture were analyzed, boundary of the hip joint was extracted to generate a three-dimensional (3D) model of the hip joint, and the assembly of common internal fixation models and hip joint models was established. Finite element simulation was then conducted, with focus on vibration characteristics. Results Vibration had a certain effect on internal fixation stability of hollow screws and locking plates. The occurrence of torsion would destroy the fixation environment of hollow screws and locking plates, resulting in a small displacement at the fracture end. In a constrained state, the modal frequency range was lower. Deformation of the vibration shape mostly occurred at proximal end of the femoral head, leading to the loosening phenomenon of internal fixation and prosthesis. A method for judging the stability of internal fixation was proposed from the perspective of vibration characteristics, and it was found that the stability of internal fixation with hollow screws was better than that of proximal locking plates. Conclusions For choosing internal fixation, influences from natural frequency of the screw and plate should be considered, so as to avoid natural frequency of the femur, which may cause resonance. The results can be used as a guidance for the selection of internal fixation materials and the design of structure and configuration.

    参考文献
    相似文献
    引证文献
引用本文

章浩伟,徐昕晟,刘颖,吴升辉,梅炯.空心钉与锁定钢板治疗股骨颈骨折的振动特性[J].医用生物力学,2022,37(2):244-249

复制
分享
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2021-03-04
  • 最后修改日期:2021-04-07
  • 录用日期:
  • 在线发布日期: 2022-04-27
  • 出版日期:
关闭